[{"data":1,"prerenderedAt":313},["ShallowReactive",2],{"/docs/jobs/firejob/setup/station-setup":3,"/docs/jobs/firejob/setup/station-setup-surround":302,"/docs/jobs/firejob/setup/station-setup-implemented-suggestions":312},{"id":4,"title":5,"body":6,"description":292,"extension":293,"head":294,"implementedSuggestions":294,"meta":295,"navigation":296,"path":297,"schemaOrg":294,"seo":298,"sitemap":299,"stem":300,"__hash__":301},"docs/1.docs/0.jobs/3.firejob/2.setup/3.station-setup.md","Station Setup",{"type":7,"value":8,"toc":279},"minimark",[9,14,18,40,44,47,68,72,79,90,97,101,104,154,160,164,167,186,190,193,220,224,248,252],[10,11,13],"h2",{"id":12},"station-planning","Station planning",[15,16,17],"p",{},"Sky Fire Job relies on the shared Sky Jobs Base job infrastructure. Before players can work normally, confirm that each firefighter station has:",[19,20,21,25,28,31,34,37],"ul",{},[22,23,24],"li",{},"A valid firefighter job in the framework",[22,26,27],{},"Duty access for the intended grades",[22,29,30],{},"A garage vehicle catalog",[22,32,33],{},"Storage access for operational items",[22,35,36],{},"Wardrobe access for protective gear",[22,38,39],{},"Dispatch visibility for on-duty firefighters",[10,41,43],{"id":42},"minimum-operational-setup","Minimum operational setup",[15,45,46],{},"For a practical first station, configure at least:",[19,48,49,56,59,62,65],{},[22,50,51,52],{},"One firefighter job such as ",[53,54,55],"code",{},"firefighter",[22,57,58],{},"One purchasable or shared station vehicle",[22,60,61],{},"One storage with the required cleanup and rescue items",[22,63,64],{},"One wardrobe or outfit source that matches the configured protective gear components",[22,66,67],{},"One usable fire scene or test area near hydrants",[10,69,71],{"id":70},"recommended-vehicle-setup","Recommended vehicle setup",[15,73,74,75,78],{},"The default fallback vehicle entry includes a ",[53,76,77],{},"firetruk"," with:",[19,80,81,84,87],{},[22,82,83],{},"Water tank enabled",[22,85,86],{},"Foam tank enabled",[22,88,89],{},"Air bottle slots",[15,91,92,93,96],{},"If you replace the default truck, review the hose offsets, hydrant supply offsets, tank sizes, and refill expectations in ",[53,94,95],{},"Config.Hose.vehicles",".",[10,98,100],{"id":99},"required-station-stock","Required station stock",[15,102,103],{},"A basic station should stock these default items:",[19,105,106,111,116,121,126,132,137,142,148],{},[22,107,108],{},[53,109,110],{},"oil_absorbent",[22,112,113],{},[53,114,115],{},"broom",[22,117,118],{},[53,119,120],{},"foam_canister",[22,122,123],{},[53,124,125],{},"rescue_cushion",[22,127,128,131],{},[53,129,130],{},"lighter"," when manual ignition testing is allowed",[22,133,134],{},[53,135,136],{},"glas_hammer",[22,138,139],{},[53,140,141],{},"hydrualic_spreader",[22,143,144,147],{},[53,145,146],{},"fire_air_bottle"," while the default inventory-backed SCBA requirement is enabled",[22,149,150,153],{},[53,151,152],{},"fire_protective_mask"," while the default inventory-backed wildfire-mask requirement is enabled",[15,155,156,157,96],{},"The air bottle becomes optional only when you disable ",[53,158,159],{},"Config.FireSystem.protectiveGear.breathingAir.item.enabled",[10,161,163],{"id":162},"hydrants-and-refill-flow","Hydrants and refill flow",[15,165,166],{},"The resource includes a bundled hydrant map setup. Firefighters can supply hoses through supported hydrant props and, when enabled, portable pump logic.",[15,168,169,170,173,174,173,178,181,182,185],{},"With the default Job Configurator enabled, place SCBA refill stations through\n",[53,171,172],{},"/jobconfig"," → ",[175,176,177],"strong",{},"Fire Jobs",[175,179,180],{},"Fire Stations",". The legacy fire creator is available only when\n",[53,183,184],{},"Config.UseJobConfigurator"," is disabled; scenario tooling does not create station interactions.",[10,187,189],{"id":188},"testing-the-station","Testing the station",[15,191,192],{},"After configuration, test this full flow:",[194,195,196,199,202,205,208,211,214,217],"ol",{},[22,197,198],{},"Go on duty with the firefighter job.",[22,200,201],{},"Spawn the configured fire vehicle.",[22,203,204],{},"Access required station storage items.",[22,206,207],{},"Equip the intended protective gear.",[22,209,210],{},"Connect the hose through hydrant, pump, or truck water supply.",[22,212,213],{},"Extinguish one test fire.",[22,215,216],{},"Refill foam and breathing air if those systems are enabled.",[22,218,219],{},"Complete one rescue or cleanup workflow.",[10,221,223],{"id":222},"common-setup-mistakes","Common setup mistakes",[19,225,226,233,236,239,242],{},[22,227,228,229,232],{},"Firefighter job name in ",[53,230,231],{},"Config.Jobs"," does not exist in the framework.",[22,234,235],{},"Uniforms do not match the required gear component configuration.",[22,237,238],{},"Cleanup or rescue items are missing or use different item names.",[22,240,241],{},"Fire vehicle offsets were copied from another model without adjustment.",[22,243,244,245,96],{},"Administrators forgot to grant boss permissions with ",[53,246,247],{},"/setboss",[10,249,251],{"id":250},"related-pages","Related pages",[19,253,254,261,267,273],{},[22,255,256],{},[257,258,260],"a",{"href":259},"./installation","Installation",[22,262,263],{},[257,264,266],{"href":265},"./configuration","Configuration",[22,268,269],{},[257,270,272],{"href":271},"../features/fire-and-hose-system","Fire and Hose System",[22,274,275],{},[257,276,278],{"href":277},"../reference/inventory-items","Inventory Items",{"title":280,"searchDepth":281,"depth":282,"links":283},"",1,2,[284,285,286,287,288,289,290,291],{"id":12,"depth":282,"text":13},{"id":42,"depth":282,"text":43},{"id":70,"depth":282,"text":71},{"id":99,"depth":282,"text":100},{"id":162,"depth":282,"text":163},{"id":188,"depth":282,"text":189},{"id":222,"depth":282,"text":223},{"id":250,"depth":282,"text":251},"Prepare the firefighter station flow, job access, vehicles, storage, and operational points.","md",null,{},true,"/docs/jobs/firejob/setup/station-setup",{"title":5,"description":292},{"loc":297},"1.docs/0.jobs/3.firejob/2.setup/3.station-setup","YiOsYZZVopsLsKiFVEsr_zwyEhF9fNLkxPp01JIZZdg",[303,307],{"title":266,"path":304,"stem":305,"description":306,"children":-1},"/docs/jobs/firejob/setup/configuration","1.docs/0.jobs/3.firejob/2.setup/2.configuration","Understand the Job Configurator, firejob feature toggles, static settings, and safe configuration workflow.",{"title":308,"path":309,"stem":310,"description":311,"children":-1},"Permissions","/docs/jobs/firejob/setup/permissions","1.docs/0.jobs/3.firejob/2.setup/4.permissions","Configure ACE-backed administrator access for Sky Fire Job commands and protected features.",[],1786395276676]